IEC TR Edition INTERNATIONAL. STANDARD. Medical device software –. Part 3: Process reference model of medical device software. IEC/TR Edition TECHNICAL. REPORT. Medical device software –. Part 1: Guidance on the application of ISO to medical device. I want to know if IEC can be used for risk management our software or it is for medical products with software (not stand alone).
Author: | Zuluzuru Zulkicage |
Country: | Oman |
Language: | English (Spanish) |
Genre: | Finance |
Published (Last): | 7 July 2013 |
Pages: | 469 |
PDF File Size: | 14.83 Mb |
ePub File Size: | 14.16 Mb |
ISBN: | 966-1-52359-120-5 |
Downloads: | 95109 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Vudolkis |
Application of risk management to medical devices BS EN BS EN ISOrecognized worldwide by regulators, is widely acknowledged as the principal standard to use when performing medical device risk management. Please first verify your email before subscribing to alerts. Life durabilityHazards, Electrical ie, Computer technology, Equipment safety, Life cycle, Quality assurance systems, Software engineering techniques, Safety measures, Maintenance, Risk assessment, Medical equipment, Electrical medical equipment, Design, Quality management, Computer software.
Find Similar Items This product falls into the following categories.
If the document is revised or amended, you will be notified by email. Much of the task of software risk management consists of identifying those sequences of events that can lead to a hazardous situation and identifying points in the sequences of events at which the sequence can be interrupted, preventing harm or reducing its probability.
As the voice of the U. Software sequences of events which contribute to hazardous situations may fall into two 8002. Risk management is always a challenge and becomes even more challenging when software is involved.
Even though ISO and this technical report focus on medical devices, this technical report could also be used to implement a safety risk management process for all software in the healthcare environment independent jec whether it is classified as a medical device. It is important to understand that software is not itself a hazard, but software may contribute to hazardous situations. It includes ISO A sequences of events representing unforeseen software responses to inputs errors in specification of the software.
Click to learn more. Symbols to be used with medical device labels, labelling, and information to be supplied Symbol development, selection and validation. Since it is very difficult to estimate the probability of software 800022 that could contribute to hazardous situations, and since software does not fail randomly in use due to wear and tear, the focus of software aspects of risk analysis should be on identification of potential software functionality and anomalies that could result in hazardous situations — not on estimating probability.
Please download Chrome or Firefox or view our browser tips.
Guidance on the application of ISO to medical device software Status: Search all products by. Need more than one copy? This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. Complex software designs can permit complex sequences of events which may contribute to hazardous situations. The faster, easier way to work with standards. Proceed to Checkout Continue Shopping.
Subscription pricing is determined by: This package can be to implement a safety risk management process for all software in the healthcare environment independent of whether it is classified as a medical device.
PD IEC/TR 80002-1:2009
Learn more about the cookies we use and how to change your settings. Software sequences of events which contribute to hazardous situations may fall into two categories: Accept and continue Learn more about the cookies we use and how to change your settings. This standard is also available to be included in Standards Subscriptions.
Establishing the safety and effectiveness of a medical device containing software requires knowledge of what ie software is intended to do and demonstration that the implementation of the software fulfils those intentions without causing any unacceptable risks.
The content of these two standards provides the foundation for this technical report. A sequences of events representing unforeseen software responses to inputs errors in specification of the software B sequences of events arising from incorrect coding errors in implementation of the software.
Areas already covered by existing or planned standards, e. Take the smart route to manage medical device compliance.
Your basket is empty. The following clauses contain additional details regarding the specifics of software and provide guidance for understanding ISO These categories are specific to software, arising from the difficulty of correctly specifying and implementing a complex system and the difficulty of completely verifying a complex system.
Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. You may 800002 issues viewing this site in Internet Explorer 9, 10 or Your Alert Profile lists the documents that will be monitored. Software should always be considered in a system perspective and software risk management cannot be performed in isolation from the system.
Risks arising from 800002 anomalies need most often to be evaluated on the severity of the harm alone. You may delete a document from your Alert Profile at any time. You can download and open this file to your own computer but DRM prevents opening this file on another 800022, including a networked server.
IEC/TR and ISO Medical Devices Software Package
Standards Subsctiption may be the perfect solution. You may find similar items within these categories by selecting from the choices below:. Please first log in with a verified email before subscribing to alerts.
We use cookies to make our website easier to use and to better understand your needs.
Software is often an integral part of medical device technology.